上海自動化(hua)儀表(biao)有(you)限(xian)公司(si)自動化(hua)儀表(biao)三廠熱電阻(zu)是(shi)利用物質在(zai)(zai)溫(wen)(wen)度(du)(du)(du)變(bian)化(hua)時本身電阻(zu)也隨著發生變(bian)化(hua)的特(te)性(xing)來測(ce)量溫(wen)(wen)度(du)(du)(du)的。熱電阻(zu)的受(shou)熱部分(感溫(wen)(wen)元件)是(shi)用細(xi)金屬(shu)絲均(jun)勻地雙繞在(zai)(zai)絕緣材料制(zhi)成的骨(gu)架(jia)上,當被測(ce)介(jie)質中(zhong)(zhong)有(you)溫(wen)(wen)度(du)(du)(du)梯度(du)(du)(du)存在(zai)(zai)時,所(suo)(suo)測(ce)得(de)的溫(wen)(wen)度(du)(du)(du)是(shi)感溫(wen)(wen)元件所(suo)(suo)在(zai)(zai)范圍(wei)內介(jie)質層中(zhong)(zhong)的平均(jun)溫(wen)(wen)度(du)(du)(du).特 點統一設(she)計(ji)產品,接口尺寸通用(yong),互換性好;采(cai)用裝配式結構,零件分解性好,維修方便;更換易損件成本低;規(gui)格齊全,性能穩定可(ke)靠。絕緣電阻裝配(pei)鉑熱電(dian)阻的常溫絕(jue)緣(yuan)電(dian)阻應不小于100MΩ裝配銅熱(re)電阻(zu)的常溫絕緣電阻(zu)應不小于50MΩ常溫絕緣(yuan)電(dian)阻的試(shi)驗電(dian)壓為10~100V DC。自熱影響:鉑(bo)電(dian)(dian)阻允許(xu)通過(guo)的*電(dian)(dian)流為(wei)5mA,由此產生的溫升不大于0.3℃。熱(re)響應時(shi)間:在溫度(du)出現階(jie)躍(yue)變(bian)化時(shi),熱(re)電阻的(de)輸(shu)出變(bian)化至相當于該階(jie)躍(yue)變(bian)化的(de)50%,所需要的(de)時(shi)間,稱為熱(re)響應時(shi)間,用(yong)τ0.5表示。熱電阻時間常數
熱惰性(xing)級(ji)別 | 時間(jian)常(chang)數(秒) | 熱惰(duo)性級別(bie) | 時間常數(秒) |
Ⅰ | 90-180 | Ⅲ | 10-30 |
Ⅱ | 30-90 | Ⅳ | 10 |
熱電阻(zu)的(de)公(gong)稱壓力:一般是指在工作溫(wen)度下保護管(guan)所(suo)能承受的(de)靜態外壓而不破裂。熱電阻(zu)*小插入深度(du):應(ying)不(bu)小于其保護套管外徑的8-10倍。絕緣(yuan)電(dian)阻(zu):當周圍空氣溫度為15-35℃,相(xiang)對(dui)濕度<80%時(shi),絕緣(yuan)電(dian)阻(zu) 20兆歐(ou)(電(dian)壓(ya)100V)。具有防濺(jian)式接線盒(he)的(de)絕緣電阻應2兆(zhao)歐(電壓100V)熱電阻(zu)感溫元件在(zai)0℃ 時(shi)電阻(zu)值(R0)及其與在(zai)100℃ 時(shi)的電阻(zu)值(R100)比值:比值=R100/R分度號為Pt10、Pt100時;R100 /R0 =1.3850±0.001分度號為Cu50、Cu100時;R100 /R0 =1.3850±0.002
021-56699281